IP54 or IP65 Beside a Bottle Rinser? A Component Table

IP54 is a weak default for a labeler standing beside a bottle rinser, and IP65 on a quotation is usually a cabinet figure rather than a machine figure. An ingress protection rating describes an enclosure. IEC 60529, the standard behind the IP code, tests a case, a door seal and a gland, not an assembly with an open label web. A labeler therefore carries six ratings at once: cabinet, motors, sensors, HMI, label path and conveyor bearings. This page turns those six into a table a buyer can sign, names the washdown chemistry that ruins a stainless frame before water does, and ends with the acceptance pack that proves each line.

Can a Labeling Machine Hold IP65 as a Whole Assembly?

A whole-machine IP rating is a claim that every opening on the assembly survives the same jet, and a labeler cannot meet that claim. The label web must leave the reel, pass a peel plate, cross an open gap and land on a bottle, so the web path is an opening by design. IEC 60529 rates an enclosure: the cabinet door, the gland plate, the HMI bezel. A machine builder who writes IP65 for the whole machine describes the cabinet and leaves the web path, the stepper motors and the sensors unstated. That gap becomes a dispute at acceptance, when a buyer sprays the frame and finds water in the photo-eye bracket. Three parties then argue about scope: the buyer who wrote IP65, the integrator who quoted a machine, and the panel shop that certified a cabinet. The practical fix is a component table, one line per part, with the level that part can hold and the protection it needs where it cannot. HiPaks answers the IP question part by part in the quotation, and the trial run video sent before shipment shows the machine on the buyer’s own bottles.

Which IP Number Fits Your Rinse Method?

A rinse method is the cleaning routine the room imposes, and the routine sets the number rather than the name of the room. A manual hose at low pressure is a splash event, which IPX4 covers. A foam lance followed by a low pressure rinse is a jet event, which IPX5 covers. A washdown station with a trigger nozzle on a short hose is a powerful jet, which IPX6 covers. A dairy or food line with a high pressure, high temperature station sits in IPX9K territory. Read the method from the cleaning SOP, not from the room class, because two rooms with the same floor drain can use different lances. The table below turns that reading into line items a fabricator and a panel shop can each price.

Component IP table for a bottle labeler

A component table is the document that replaces the single number, and it carries three columns: the part, the level that part can hold, and what to write when the level is short. Seven parts cover most bottle labelers.

Part Level it can hold What to write if the level is short
Electrical cabinet IP65 with a gasketed door and a gland plate IP66 where the jet hits the door, plus a drain and a breather
Servo and stepper motors IP65 as supplied by the motor maker IP66 shroud, or move the motor out of the lance path
Photoelectric and gap sensors IP67 on most SICK and Panasonic heads IP69K only with a stainless sensor and a sealed bracket
HMI and touch screen IP65 flush panel, IP66 with a sealed bezel Stainless hood and a sloping top above the screen
Label web path No IP rating is possible Guard the reel, drain the peel plate, accept an open path
Conveyor and bearings IP65 with sealed units Washdown bearings, or a removable belt section
Cable glands and connectors IP68 glands, IP67 connectors Drip loop plus a sealed junction box

What the water digits actually test

The second digit of an IP code names the water test, and the conditions explain why IP65 and IP66 differ on a washdown line. IPX4 plays a splash or spray from an oscillating tube or a nozzle. IPX5 directs a 6.3 mm nozzle at 12.5 litres per minute from about 3 metres. IPX6 swaps to a 12.5 mm nozzle at 100 litres per minute, roughly eight times the flow. IPX9K goes further again, with water at 80 °C delivered at 80 to 100 bar from four angles. A rinse lance on a food line reaches the IPX6 range, and a steam and chemical station reaches IPX9K. According to IEC 60529, the digits describe a test rather than a cleaning shift, so a pass on a new gasket says nothing about the same cabinet after two years of alkaline foam.

Automatic labeling machine on a food and beverage line with an open label web path beside a bottle conveyor, the part of the assembly that no single IP rating can cover

Why Does Washdown Chemistry Fail the Frame First?

Washdown chemistry is the part of cleaning that removes metal, and it acts before water reaches a seal. Alkaline foam cleaners run at pH 11 to 13 and attack aluminium guards and zinc plated fasteners. Chlorinated sanitisers release chloride ions, and chloride is the ion that pits grade 304 stainless. Grade 316L carries 2% to 3% molybdenum, per ASTM A240, and 304 carries 18% chromium and 8% nickel without a deliberate molybdenum addition. For example, a 316L frame with a ground weld outlasts a 304 frame with an open crevice beside a chlorinated rinse. Condensation is the second path. A cabinet sealed to IP66 traps moisture that enters on a warm, humid day, and that water sits on the bottom plate. A breather, a drain plug and a small heater deal with the water, while a fan filter unit makes the problem worse by pulling washdown mist inside.

How Should 304 and 316 Be Written on the Drawing?

A stainless grade on its own is not a specification, and four clauses turn 304 or 316 into something a fabricator can be held to. First, surface roughness: EHEDG hygienic design guidance puts the target for product contact surfaces at Ra 0.8 micrometres or smoother, and a brushed mill finish does not reach that figure. Second, welds: continuous welds, ground flush, then pickled and passivated, because a crevice at a weld is where chloride attack starts. Third, drainage: a slope of 1 to 2 degrees toward a drain, and no flat top surface where water stands. Fourth, legs and feet: sealed tubular legs with hygienic caps, or adjustable feet in sealed housings, never an open tube standing on the floor. Write each clause as a line in the specification table, with a unit and a test beside it. Under OSHA 1910.304, a wet location also changes the electrical requirement, so the drawing and the panel schedule have to agree.

What Proves the Rating at Acceptance?

An acceptance pack is the evidence set that proves each line of the component table, and the pack has four items. Item one is the IP test report, naming the part, the level and the test standard with the test house and the date. Item two is the nameplate or certificate page for each purchased part, such as a SICK sensor or a Panasonic photoelectric head. Item three is the drawing revision that shows the drains, the breathers and the gland plates. Item four is the field washdown record: spray the cabinet for ten minutes with the cleaning agent at the dilution the SOP states, then open the door and place indicator paper on the bottom plate. A colour change on the paper is a failed seal, and the fix belongs to the supplier rather than to maintenance.

Four checks that take one shift

Four checks close the IP question on site, and each takes minutes rather than a day.
Step 1: compare the delivered nameplate with the component table line by line, because a missing level is a non conformance.
Step 2: lift each gland plate cover, confirm the gasket is continuous, and confirm the gland matches the cable diameter.
Step 3: run the rinse SOP for ten minutes at the lance pressure the room uses, then check indicator paper inside the cabinet and behind the HMI bezel, because the 2013 consolidated edition of IEC 60529 holds each jet test surface for 3 minutes.
Step 4: photograph the drains and the breather, and file the photos with the drawing revision.
For example, a cabinet that passes Step 3 on delivery and fails in month four usually has a blocked drain rather than a failed gasket. Record the four results on one sheet, sign it with the buyer and the integrator, and attach it to the factory acceptance test file.

Is IP66 the same as NEMA 4X?

An IP rating and a NEMA type are different documents, and the numbers do not map one to one. NEMA 250 describes a US enclosure type, and NEMA 4X adds a corrosion resistance test that no IP digit covers. A cabinet marked IP66 has passed jet testing under IEC 60529, and the same cabinet may or may not pass the NEMA 4X hose and corrosion tests. For a US food plant, write both: IP66 for the jet and NEMA 4X for the washdown chemicals, then ask for the listing that covers both claims.

Does IP69K make sense on a labeler?

IP69K is a high pressure, high temperature test, and the rating covers the parts the jet can reach rather than the label web. A machine with an IP69K cabinet, IP69K motors and an open web path is still an open machine at the peel plate. Buy IP69K for the parts that face the lance, and write a stainless hood and a drain for the rest. A whole machine IP69K claim on a labeler is a claim about parts, so the quotation should name which parts carry it.

What about an IP54 cabinet on a dry line?

IP54 is enough where the line is dry and the cleaning is a damp cloth, and it is a defensible choice for a secondary packing hall. IP5X means dust protected rather than dust tight, so a fine powder room needs IP6X. IPX4 covers splash from any direction, which is what a wipe down produces. The mistake is carrying IP54 into a room with a floor drain and a hose, where the splash becomes a jet at ankle height. Match the number to the food and beverage line cleaning SOP, and write the SOP revision on the drawing.

Two actions close the topic. First, replace the single IP number on the enquiry with the seven-line component table, so each supplier prices the same scope. Second, book the washdown check into the acceptance agenda beside the label accuracy run, because a rating that is never tested is a sentence in a brochure. HiPaks quotes the level per part and includes the cabinet condition in the trial run video, which leaves the buyer holding evidence rather than a claim. Ask for a quotation with the cleaning SOP attached, and the table comes back filled in.

Get a factory quote for your own container.

Send the container, label size and target speed. You get a short list of machine options, an indicative price and a free test-run plan on your own labels.

Get a Factory Quote Request a Free Test-Run Video

Share

Related reading

Keep reading.

More guides from the same category, chosen for the machine types and container details they cover.

Automatic Labeling Guides

Main Switch Off, Head Still Drops: What Must Be Locked Out?

Isolation is the state in which every energy source at a machine is held off at a point a lock fits and proved dead. The label head still drops after the main switch is off because a switch ends the control sequence, not the energy. Four classes survive the panel: mains with the drive’s residual ... <a title="Main Switch Off, Head Still Drops: What Must Be Locked Out?" class="read-more" href="https://hipaks.com/energy-isolation-lockout-points-before-clearing-a-jam/" aria-label="Read more about Main Switch Off, Head Still Drops: What Must Be Locked Out?">Read more</a>

Nov 26, 2026 · 10 min read
Read guide
Automatic Labeling Guides

Front, Back and Neck Labels on One Machine: Which Order?

Three labels need a sequence before they need a tolerance. The order holding at inspection is orientation, then front, then back, then neck. The neck head sits downstream of the two body heads, and every figure is measured from a named parent. Front and back can share one bottle datum. The neck label cannot, so ... <a title="Front, Back and Neck Labels on One Machine: Which Order?" class="read-more" href="https://hipaks.com/three-label-station-sequence-datum-chain-quote/" aria-label="Read more about Front, Back and Neck Labels on One Machine: Which Order?">Read more</a>

Nov 25, 2026 · 10 min read
Read guide
Automatic Labeling Guides

Clear Space Around a Labeler: Who Gives Which Figure?

A clear-space envelope is the set of empty volumes around a labeler that must stay empty for loading, guarding, maintenance and measurement. No single party owns the whole envelope. The drawing in hand shows only the machine base. Five faces have to be dimensioned before a slab is poured or an anchor bolt is set. ... <a title="Clear Space Around a Labeler: Who Gives Which Figure?" class="read-more" href="https://hipaks.com/labeler-clear-space-envelope-roll-change-maintenance-access/" aria-label="Read more about Clear Space Around a Labeler: Who Gives Which Figure?">Read more</a>